Advance Ceiling-Mount Horn Strobes

The SpectrAlert Advance ceiling-mount horn strobes are rich with features guaranteed to cut installation time and maximize profits. Features include a universal mounting plate with a preliminary snap-in feature to hold the product in place for the screw attachment, 11 field- selectable candela settings, dual voltage in one product, and rotary switches to select horn tone and volume settings. SpectrAlert Advance horn strobes are listed to UL 1971 and UL 464. Model numbers with a “K” suffix are listed to UL 1638 and NEMA 4X for outdoor use.

For all SpectrAlert Advance models, a -P suffix denotes plain housing (no “FIRE” print); -SP denotes “FUEGO” -printed housing. Outdoor units with model numbers ending with -R do not include weatherproof back boxes. Outdoor units with model numbers ending in K do include weatherproof back boxes.

Order

Description

UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Standard Candela Range (15–115 cd)

Red Model Number: PC2R, PC2R-P | Outdoor: PC2WK

White Model Number: PC2W, PC2W-P, PC2W-SP | Outdoor: PC2WK

DC Input- Temporal High
8-17.5 Volts
15- 137
15/75- 147
16-33 Volts
15- 79
15/75- 90
30- 107
75- 176
95- 194
110-212
115- 218

DC Input- Temporal Medium
8-17.5 Volts
15- 132
15/75- 144
16-33 Volts
15- 69
15/75- 80
30- 97
75- 157
95- 182
110- 201
115-210

DC Input- Temporal Low
8-17.5 Volts
15- 132
15/75- 143
16-33 Volts
15- 66
15/75- 77
30- 93
75- 154
95- 179
110- 198
115-207

DC Input- Non Temporal High
8-17.5 Volts
15- 141
15/75- 152
16-33 Volts
15-91
15/75- 100
30- 116
75- 176
95- 201
110- 221
115-229

DC Input- Non Temporal Medium
8-17.5 Volts
15- 133
15/75- 145
16-33 Volts
15- 75
15/75- 85
30- 102
75- 163
95-187
110-207
115- 216

DC Input- Non Temporal Low
8-17.5 Volts
15- 131
15/75-144
16-33 Volts
15- 68
15/75- 79
30- 96
75- 156
95- 182
110- 201
115- 210

FWR Input- Temporal High
8-17.5 Volts
15- 136
15/75- 155
16-33 Volts
15- 88
15/75- 97
30- 112
75- 168
95- 190
110-  210
115- 218

FWR Input- Temporal Medium
8-17.5 Volts
15- 129
15/75- 152
16-33 Volts
15-78
15/75- 88
30-103
75-  160
95- 184
110- 202
115- 211

FWR Input- Temporal Low
8-17.5 Volts
15- 129
15/75- 151
16-33 Volts
15- 76
15/75- 86
30- 101
75- 160
95- 184
110-194
115-201

FWR Input- Non Teporal Low
8-17.5 Volts
15- 142
15/75- 161
16-33 Volts
15-103
15/75- 112
30- 126
75- 181
95- 203
110- 221
115-229

FWR Input- Non Tmporal Medium
8-17.5 Volts
15- 134
15/75- 155
16-33 Volts
15- 85
15/75- 95
30- 110
75- 166
95- 189
110- 208
115- 216

FWR Input- Non Tmporal Low
8-17.5 Volts
15- 132
15/75- 154
16-33 Volts
15- 80
15/75- 90
30- 105
75- 161
95- 184
110- 202
115- 211